We are leading manufacturer & supplier of PFA / FEP Lined Diaphragm Valve in India
Click on Image to Enlarge Ask PriceValve Size (mm) | L | H | H1 | T | OD | ID | R/F | P.C.D | Holes Dia HD | No. of Hole NH |
25 | 133 | 115 | 95 | 14.3 | 108 | 25 | 51 | 79.4 | 16 | 4 |
40 | 154 | 154 | 115 | 17.5 | 127 | 40 | 73 | 98.4 | 16 | 4 |
50 | 160 | 160 | 140 | 19 | 152.4 | 50 | 92 | 120.6 | 19 | 4 |
80 | 235 | 235 | 220 | 23.8 | 190.5 | 75 | 127 | 152.4 | 19 | 4 |
100 | 260 | 260 | 240 | 23.8 | 228.6 | 95 | 157 | 190.5 | 19 | 8 |
150 | 370 | 370 | 370 | 25.4 | 279.4 | 145 | 216 | 241.3 | 22.2 | 8 |
Teflon® PFA / FEP LINED DIAPHRAGM VALVE AS PER ANSI 150#.
GENERAL SPECIFICATIONS
SERVICE TEMPERATURE OF LINED DIAPHRAGM VALVE
- PFA : 230° C.
- FEP : 180° C.
TECHNICAL SPECIFICATIONS OF LINED DIAPHRAGM VALVE
- Lining Thickness : Minimum 3.00 over all wetted parts.
- Length of Diaphragm Valve : BS 5156.
TEST & INSPECTION DATA OF LINED DIAPHRAGM VALVE
- Hydraulic Test – Body (Shell) : 20 Kg/Cm².
- Seat : 10 Kg/Cm².
- Pneumatic Test – Seat : 6 Kg/Cm².(Class VI Sealing)
- Spark Test : 15 K.V D.C.
Make Enquiry