We are leading manufacturer & supplier of Lined Header in India
Click on Image to Enlarge Ask PriceMATERIAL SPECIFICATIONS
- Flange : Plate Flange From Carbon Steel Plates As Per ASTM A 105 / IS 2062.
- Pipe : Simless Carbon Steel Pipes As Per ASTM A – 106, Sch. 40.
- Lining : PFA / FEP
DIMENSION SPECIFICATIONS
- All Dimension are in mm.
- Pipe Dimension as Per ANSI B 36.10.
- Liner Thickness Minimum 3.0 mm.
- Header Length Maximum 600 mm.
- Flange Size : On Party Requirement.
TEST & INSPECTION DATA
- Hydraulic Test – Body (Shell) : 20 Kg/Cm².
- – Seat : 10 Kg/Cm².
- Spark Test : 10 K.V D.C.
Visual Check / Dimension Check.
Question?Make Enquiry